Sign In | Join Free | My wpc-board.com
China Zhongdong Cable Co., Ltd. logo
Zhongdong Cable Co., Ltd.
Zhongdong Cable Co., Ltd.
Verified Supplier

1 Years

Home > Aluminium Conductor Cable >

Single Core Aluminium Conductor Power cable Medium Voltage Underground Cable for Electrical Use

Zhongdong Cable Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Single Core Aluminium Conductor Power cable Medium Voltage Underground Cable for Electrical Use

Brand Name : Zhongdong

Model Number : YJLHV62 YJLHV22

Certification : IEC,CE,ISO

Place of Origin : Hebei,China

MOQ : Negotiable

Price : Negotiable

Payment Terms : L/C,T/T

Supply Ability : 100KM/Week

Delivery Time : 10Days

Packaging Details : wooden drums

Conductor : 8000 Aluminium Alloy

Insulation : PVC

Voltage Rating : 3.6kV-35kV

Outer Sheath Colour : Black

Temperature : Fixed -40°C to +80°C

No of Core : 1,3

Contact Now

Single Core Aluminium Conductor Power cable Medium Voltage Underground Cable for Electrical Use


APPLICATION

Single-core aluminium conductor power cables with medium voltage ratings (typically 6kV–36kV) are widely used in the following scenarios‌

  • Power Distribution Networks
  • Industrial Facilities
  • Infrastructure Projects
  • Renewable Energy


CONSTRUCTION

  • Conductor:Round compacted conductors
  • Conductor Shield:Semi conductive shielding material (below 500mm2) Semi conductive tape+semi conductive shielding material (500mm2 and above)
  • Insulation:Polyvinyl chloride (PVC)
  • Insulation Shield:Peelable semiconducting shielding material
  • Metal Shield Layer:Copper Tape Copper Wire(35kV 500mm2 above)
  • Filler: Polypropylene(PP) mesh filling rope
  • Binder Tape: Non hygroscopic straps
  • Armouring: Steel Tape(Single core) Galvanized steel tape(3 core)
  • Outer sheath: 90 Polyvinyl chloride (PVC)


Single Core Aluminium Conductor Power cable Medium Voltage Underground Cable for Electrical UseSingle Core Aluminium Conductor Power cable Medium Voltage Underground Cable for Electrical Use




CHARACTERISTIC

  • Voltage Rating Uo/U
  • 3.6/6(7.2)kV, 6/6(7.2)kV, 6/10(12)kV, 8.7/10(12kV), 8.7/15(17.5)kV, 12/20(24)kV,18/30(36)kV, 21/35(40.5)kV, 26/35(40.5)kV
  • Maximum operating temperature of conductor:+90℃
  • Operating ambient temperature: -15℃~+55
  • Cable laying temperature:Not less than 0℃(When the ambient temperature is below 0℃, the cable should be preheated.)
  • Minimum Bending Radius: Single Core 15D Three Core 12D


SPECIFICATION

3.6/6kV Cable Structure Parameters

Specs
mm²

Conductor diameter
mm

Outer thickness of insulation
±1.0mm

Approx outer diameter of cable
mm

Approx cable weight
kg/km

1×25

6.0±0.1

12.2

21.1

604

1×35

6.6±0.2

12.8

21.7

670

1×50

7.6±0.2

13.8

22.9

759

1×70

9.2±0.2

15.4

24.5

869

1×95

10.9±0.2

17.1

26.4

993

1×120

12.2±0.2

18.4

27.7

1110

1×150

13.6±0.2

19.8

29.2

1253

1×185

15.2±0.2

21.4

30.8

1412

1×240

17.4±0.2

23.8

33.4

1669

1×300

19.5±0.2

26.3

37.5

2306

1×400

22.0±0.2

29.2

40.6

2758

1×500

24.8±0.2

33.2

45.0

3296

1×630

28.2±0.2

366

48.7

3875

1×800

34.0±0.2

42.4

54.7

4663

6/6kV(6/10kV) Cable Structure Parameters

Specs
mm²

Conductor diameter
mm

Outer thickness of insulation
±1.0mm

Approx outer diameter of cable
mm

Approx cable weight
kg/km

1×25

6.0±0.1

15.6

23.1

687

1×35

6.6±0.2

16.2

23.7

756

1×50

7.6±0.2

17.2

24.9

849

1×70

9.2±0.2

18.8

26.5

963

1×95

10.9±0.2

20.5

28.3

1103

1×120

122±0.2

21.8

29.6

1224

1×150

13.6±0.2

23.2

31.2

1371

1×185

152±0.2

24.8

328

1536

1×240

17.4±0.2

27.0

36.5

1788

1×300

19.5±0.2

29.1

38.7

2401

1×400

22.0±0.2

31.6

41.6

2845

1×500

24.8±0.2

35.2

45.4

3332

1×630

282±0.2

38.6

49.1

3913

1×800

34.0±0.2

44.4

55.1

4704

8.7/10kV(8.7/15kV) Cable Structure Parameters

Specs
mm²

Conductor diameter
mm

Outer thickness of insulation
±1.0mm

Approx outer diameter of cable
mm

Approx cable weight
kg/km

1×25

6.0±0.1

17.6

25.1

786

1×35

6.6±0.2

18.2

25.9

857

1×50

7.6±0.2

19.2

26.9

954

1×70

9.2±0.2

20.8

28.6

1085

1×95

10.9±0.2

22.5

30.3

1218

1×120

12.2±0.2

23.8

31.8

1356

1×150

13.6±0.2

25.2

332

1494

1×185

15.2±0.2

26.8

36.3

1679

1×240

17.4±0.2

29.0

38.6

2291

1×300

19.5±0.2

31.1

40.9

2581

1×400

22.0±0.2

33.6

43.8

3036

1×500

24.8±0.2

37.2

47.7

3558

1×630

28.2±0.2

40.6

51.3

4130

1×800

34.0±0.2

46.4

57.4

4968

Contact us for 12/20kV 18/30kV 21/ 35kV and 26/35kV


OUR PLANTS

Single Core Aluminium Conductor Power cable Medium Voltage Underground Cable for Electrical Use


APPLICATION


Single Core Aluminium Conductor Power cable Medium Voltage Underground Cable for Electrical Use



PROJECT


Single Core Aluminium Conductor Power cable Medium Voltage Underground Cable for Electrical Use


PACKAGE


Single Core Aluminium Conductor Power cable Medium Voltage Underground Cable for Electrical Use


PARTNER


Single Core Aluminium Conductor Power cable Medium Voltage Underground Cable for Electrical UseSingle Core Aluminium Conductor Power cable Medium Voltage Underground Cable for Electrical Use


FAQ

Q‌: What is the voltage rating of single-core aluminum alloy medium voltage cables?
A : Typically rated for ‌6kV–36kV‌, suitable for industrial and urban power distribution networks

Q:Why choose aluminum alloy conductors over pure aluminum?
A: Aluminum alloys (e.g., AAAC) offer ‌higher tensile strength‌ and ‌better corrosion resistance‌, reducing sagging in overhead line

Q‌. Can single-core cables be installed underground?
A. Yes, but require ‌steel tape armor (STA)‌ or ‌swa (steel wire armor)‌ for mechanical protection

Q. How to mitigate induced currents in single-core MV cables?
A. Use ‌cross-bonding‌ or ‌non-magnetic piping‌ to prevent eddy current losses

Q‌. Are these cables suitable for renewable energy projects?
A. Yes, widely used in ‌wind/solar farms‌ for connecting generators to substations

Q‌. How to specify conductor size (e.g., 120mm²)?
A. Based on ‌load current‌ and ‌voltage drop‌ calculations; 120mm² is common for industrial loads



Product Tags:

single core aluminium power cable

      

medium voltage underground cable

      

aluminium conductor electrical cable

      
Wholesale Single Core Aluminium Conductor Power cable Medium Voltage Underground Cable for Electrical Use from china suppliers

Single Core Aluminium Conductor Power cable Medium Voltage Underground Cable for Electrical Use Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Zhongdong Cable Co., Ltd.
*Subject:
*Message: